On the yard
With a Danilith-residence you will rapidly be under a roof
Yard preparation and ground works
measuring and inserts with laser technology
all excavations
Foundations
Prestressed foundation beams deposited on site
Floor plate approx. 10 cm in reinforced concrete
Insulation of the complete surface
Copper ground loop around the entire residence
Sewerage
Piping and fittings in PVC
Supervision points up to the chamber
Direct connection of toilets to the sewerage system
Including rainwater chamber (5.000 l) and supply line (15 m)
Blue stones
Skirting board in sanded blue stones around the whole building
Window sills (5 cm) in sanded blue stones
Door sills (8 cm) in sanded blue stones
Roofing and ceilings
Benor-approved tiles in baked soil
Standard: roof trusses provided with insulation roof with dust- and tile laths , ceiling in plasterboards with insulation layer
Roof implementations with a concrete slab for attic access: roofsides, 18 cm insulation with vapor screen, roofinsulation plus dust- and tile laths, ceiling in concrete finished in spray filler
Flat roof: concrete, the necessary insulationscreens and roof sealing, ceiling finished in spray filler, aluminum roof edge profile
Zinc work - roof
Gutters and rainwater drain in zinc-copper-titanium alloy (0,8 mm) in black enameled ornamental brackets
Finishing board and roof railings in meranti
Cantilever over the wall (33,5 cm) finished in meranti
Outer wall
All swinging parts are supplied with tilt and turn valve and security attachment
2 standard outer doors with security attachment (5-point connection) and 1 sliding window (2.41 m)
Tilt-up garage door with a metal frame and multiplex attachment
Cabinetwork outer wall: dark red meranti wood or in impact-proof hard PVC-white (constructed in our own workshop with hollow Wymar-profiles and galvanized steel)
Outer walls in colorized PVC or aluminum : only at extra cost
Glass work
Double super insulating, glazed and positioned with feuters and silicones (k=1,1 w/mēk)
Ventilations
According to the Energy Performance of Buildings Directive (EPBD)
Insulation
Floor: Isotherm complete surface
Wall: polyurethane plates (7 cm)
Roof with self-supporting roof panels : polyurethane plates (18 cm)
Ceiling with roof tiles: glass wool (18 cm)
Connections
Through client or through the contractor if the accounting is adapted
The connection (connection cost and piping) is not provided. The developer is accountable
Basement (if applicable)
Prefabricated basement: excavate, delivery and placing, foundation, 1 luminous spot and 1 wall socket, 2 ventilations and 1 inside door
Standard basement in the ground: ground works, foundation plate (reinforced concrete 23 cm), wall (concrete), ceiling (smooth concrete), 1 inner door per space, ventilation and draining
Garage basement: like a standard basement with an extra retaining wall, 1 automatic garage door and a visible fence by means of masonry
|
|
|